Smiths Detection - GID-3
Contact:

Smiths Detection

459 Park Ave

Bushey Watford

WD23 2BW

globalsales@smithsdetection.com

System Cost: N/A
Analysis Cost: <$1
Survey Source: Vendor Supplied Information
General Description
GID-3 is highly portable, easy to use and rapidly deployed. As well as point detection, it can monitor the integrity of collective protective systems in vehicles, command bunkers and small ships. GID-3 detects, identifies and measures the concentration levels of Chemical Warfare agents and Toxic Industrial Chemicals (TICs). Operated remotely, the GID-3 provides perimeter protection either as a stand-alone unit, or networked together using hardwired or wireless systems. Vehicle-or ship-mounted, it can monitor contamination of the outside air or alert personnel to the presence of a chemical agent in the vehicle interior.
Technical Description
GID-3 employs ion mobility spectrometry technology.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 2 components
  • Less than 5 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a toaster
  • Between 5 and 25 kg
  • Wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • Greater than 10 years expected life
  • Results cannot be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • Less than 10 µL
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • >1x10-3 mg/m3
  • 1 ppb-1 ppm
  • Possible system could identify aerosolized chemical agent
  • System currently can identify liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE