Detector Image Not Found
Average User Rating:

Alexeter Technologies - Guardian Reader System
Contact:

Alexeter Technologies

877-591-5571

www.alexeter.com

System Cost: $12,000
Analysis Cost: $26.00
Survey Source: Vendor Supplied Information
General Description
The Guardian Reader System is designed to detect and identify the following biological agents, in the field, with a 15-minute test: anthrax, ricin, botulinum toxin, staphylococcal enterotoxin B, plague, tularemia, brucella and orthopox. The Guardian Reader, part of the system is an optical reader which evaluates the test strips, documents the results and delivers a report to the user. Alternatively, the system may be supplied with the Defender TSR (Test Strip Reader) a hand-held optical reader. A protein detection test is also part of the system.
Technical Description
Hand held immunochromatographic assays that use colloidal gold labeled antibodies, optional Reader for objective evaluation and documentation.
Evaluation Criteria
THROUGHPUT:
  • Between 15 and 30 minutes for detection
  • 1 sample, <10 tests/sample per run
  • Less than 32 samples every 2 hours
  • The system or device is currently semi-automated
  • Device or system is designed for a single use
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 1 component
  • No set-up of the system is required for set-up
  • 3-5 steps are required for detection
LOGISTICS:
  • An afternoon of training and some technical skills required
  • Approximately the size of a toaster
  • Between 5 and 25 kg
  • This system is not capable of transmitting data
  • System or device has 110V electrical requirement
  • 1-2 hours battery life
OPERATIONS:
  • Can be used from 4°C to 41°C
  • Components must be stored at room temperature (27°C)
  • Performance is not influenced by relative humidity
  • Between 1 to 3 years shelf life
  • Results can be viewed in real-time
  • The system could be adapted to a fully autonomous system with significant effort
  • The system software is open but modification requires licensing
  • The system hardware is open but modification requires licensing
DETECTION:
  • Less than 50 µL
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • 10,000-100,000 CFU per mL
  • Greater than 100,000 PFU per mL
  • 10-100 ng per mL
  • Spore lysis not necessary for detection by system
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE