FLIR Systems, Inc. - Agentase Disclosure Spray for Blister Agents
Contact:

FLIR Systems, Inc.

CBRNE Detection

2240 William Pitt Way

Pittsburgh, PA 15238

412-423-2100

www.flir.com

System Cost: N/A
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
Colorimetric Enzyme-Based Spray that detects chemical agents directly on surfaces via a visible color change within 5 minutes. The formulation detects Sulfur Mustard Blister Agent (HD) with microgram sensitivity. The Blister Agent Disclosure Spray is sold in three form factors: a half-liter handheld sprayer capable of covering 5-7 square meters of surface; a man-portable sprayer, the Viper Discovery applicator, which contains approximately 2 gallons of the formulation and covers 75 – 120 square meters of surface area; and the Merlin Discovery cart-based sprayer, which holds 14 gallons and is capable of covering 500-700 square meters.
Technical Description
Colorimetric Enzyme-Based Spray that detects chemical agents directly on surfaces via a visible color change within 5 minutes.
Evaluation Criteria
THROUGHPUT:
  • Between 2 and 15 minutes for detection
  • Multiple samples, multiple tests/sample per run
  • 349-96 samples every 2 hours
  • The system could be adapted to a semi-automated system with some effort
  • Device or system is designed for a single use
  • 2 solutions, buffer, eluents, and/or reagents
  • 0 components
  • Less than 5 minutes is required for setup
  • 1-2 steps are required for detection
LOGISTICS:
  • An afternoon of training and some technical skills required
  • Approximately the size of a toaster
  • Between 1 and 5 kg
  • This system is not capable of transmitting data
  • There is no electrical requirement
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • Components must be stored at room temperature (27°C)
  • Performance is not influenced by relative humidity
  • Between 1 to 3 years shelf life
  • Results can be viewed in real-time
  • The system is not capable of autonomy
  • The system does not employ any software
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • This system does not test liquids
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE