Detector Image Not Found
Average User Rating:

Technical Associates - Hydrofracking Radiation Portable Water Monitor
Contact:

Technical Associates

7051 Eton Ave.

Canoga Park, CA 91303

POC: Robert Goldstein, President

818-883-7043

tagold@nwc.net

www.tech-associates.com

System Cost: $3,720
Analysis Cost: <$1
Survey Source: Vendor Supplied Information
General Description
Hydrofracking releases trapped radiation from underground formations into mobile water flow, including groundwater, or industry generated wastewater, sludge, or brine and surrounding soil.
The Hydrofracking Radiation Portable Water Monitor, Meda-SP, is a small light weight field monitor for on the spot measurement of water or soil samples.
Quick detection of radiation contamination in water and soil generated by the hydrofracking process:
  • Alpha, Beta, and Gamma emitters; Uranium, Radium, Potassium, and Thorium in water samples
  • Hydrofracking wastewater, sludge and brine; Roadside Chemical Spill; Industrial Accident; Improper Dumping of Industrial Waste.
  • Easy detection of surface contamination-alpha, beta, gamma; hands, boots, clothing and equipment
  • Identify personnel needing decontamination
End Users: Oil and Gs Industry, First Responders, state and federal health agencies, citizen groups, municipal utilities.
Technical Description
The Hydrofracking Radiation Portable Water Monitor features an internally mounted 2 inch pancake GM detector with window looking downward from bottom of case and an external crystal scintillation probe for detection of low energy gammas. Alpha, beta, and gamma emitters are detected. A sliding shield protects pancake detector when not in use. This system is half the weight of other systems. Submersible sensor probes for reservoir, stream or sump provide additional diversity.
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently semi-automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 1 component
  • No set-up of the system is required for set-up
  • 3-5 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a toaster
  • Less than 1 kg
  • Wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from 4°C to 37°C
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system does not employ any software
  • The system hardware is open and available for modification
DETECTION:
  • Greater than 250 µL
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • Only total dose and dose rate
  • Down to background level radiation for dose rate
  • System is used for surveying
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE