Detector Image Not Found
Average User Rating:

Technical Associates - Hydrofracking Radon Portable Air and Gas Monitor
Contact:

Technical Associates

7051 Eton Ave.

Canoga Park, CA 91303

POC: Robert Goldstein, President

818-883-7043

tagold@nwc.net

www.tech-associates.com

System Cost: $9,211
Analysis Cost: $0
Survey Source: Vendor Supplied Information
General Description
Radon gas is a common problem especially in closed places. Hydrofracking releases Radon gas which then works its way to the soil surface and then into basements and buildings. Additionally Radon gas finds its way into the gas pipeline. These avenues of escaping Radon gas cause hazardous conditions for people and animals. The need for testing has increased with the advent of hydrofracking technology. The Hydrofracking Radon Portable Air & Gas Monitor, PTG-9-RN, is a sensitive rugged, portable instrument for quick and immediate detection and measurement of airborne Radon. End Users: Oil and Gas Industry, Building Inspectors, state and federal health agencies, small labs, citizen groups, municipal utilities.
Technical Description
The Hydrofracking Radon Portable Air & Gas Monitor utilizes a subtractive balanced chamber electro - meter circuit decreasing background effects to negligible levels. Its ionized and filtered intake reduces to negligible levels spurious effects from smoke, dust and existing ionization in the air. Inlet and outlet hoses allow monitoring interiors of fume hoods, exhaust stacks, etc. The PTG-9-A-RN will measure airborne radon as free Radon gas (with or without Radon Daughters at users option) as low as 1 pCi/l.
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently semi-automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • No set-up of the system is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a carry-on luggage suitcase
  • Between 1 and 5 kg
  • Satellite and wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from 4°C to 41°C
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is open and available for modification
  • The system hardware is open and available for modification
DETECTION:
  • This system does not test liquids
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • Only total dose and dose rate
  • Down to background level radiation for dose rate
  • System is used for area air sampling
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE