Detector Image Not Found
Average User Rating:

Technical Associates - Hydrofracking Radon Portable Water Monitor System
Contact:

Technical Associates

7051 Eton Ave.

Canoga Park, CA 91303

POC: Robert Goldstein, President

818-883-7043

tagold@nwc.net

www.tech-associates.com

System Cost: $9,636
Analysis Cost: $0
Survey Source: Vendor Supplied Information
General Description
Hydrofracking releases trapped radiation, including Radon, from underground formations into mobile water flow, including groundwater, or industry generated wastewater, sludge, or brine.
Hydrofracking Radon Portable Water Monitor System, Radon-7, provides quick detection on site of Radon contamination generated by the hydrofracking process in groundwater, wastewater, sludge, and brine:
  • Also detects Alpha emitters and Thorium in water samples
  • Portable instrumentation provides quick response for: Roadside / Chemical Spill; Industrial Accident; Improper Dumping of Industrial Waste.
End Users: Oil and Gas Industry, First Responders, state and federal health agencies, citizen groups, municipal utilities.
Technical Description
The Hydrofracking Radon Portable Water Monitor System operates with a continuous water flow through the lower section of the sample head. Some of the suspended Radon gas escapes from the water due to its vapor pressure. If desired, the amount of, Radon escaping can be increased by heating, agitating, bubbling, etc. The resulting radon gas is detected by the alpha scintillation in the upper chamber. The count rate from the alpha scintillator detector is displayed on the alarming AC-DC Ratemeter. Alarm levels are user specified.
The Hydrofracking Radon Portable Water Monitor System Includes:
  • Sample Head, FLO-9
  • Alpha Scintillator, PAS-8
  • Alarming Ratemeter, LAM-10
Evaluation Criteria
THROUGHPUT:
  • Between 2 and 15 minutes for detection
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • No set-up of the system is required for set-up
  • Automatic detection
LOGISTICS:
  • An afternoon of training and some technical skills required
  • Approximately the size of a toaster
  • Between 1 and 5 kg
  • This system is not capable of transmitting data
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from 4°C to 37°C
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system is not capable of autonomy
  • The system does not employ any software
  • The system hardware is open and available for modification
DETECTION:
  • Greater than 250 µL
  • Fair specificity. System has a consistent level of false alarms (5-10%)
  • Only dose rate
  • Down to background level radiation for dose rate
  • System is used for surveying
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE