Smiths Detection - Lightweight Chemical Detector (LCD) 3.3
Contact:

Smiths Detection

459 Park Ave

Bushey Watford WD23 2BW

globalsales@smithsdetection.com

System Cost: N/A
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
Based on leading IMS technology, the LCD 3.3 is a light and versatile chemical warfare agent (CWA) and toxic industrial chemical (TIC) detector. LCD 3.3 is an advanced warning device, that alarms to gas and vapour threats detected and identified at or below immediately dangerous to life and health (IDLH) levels, by determining the agent or type, class, concentration and dosage of chemical exposure. It can also be used as a screening and survey device.
Technical Description
LCD 3.3 employs ion mobility spectrometry technology.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 2 components
  • Less than 5 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a soda can
  • Less than 1 kg
  • Wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • Greater than 10 years expected life
  • Results cannot be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • Less than 10 µL
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • > 1x10-3 mg/m3
  • 1 ppb-1 ppm
  • System currently can identify aerosolized chemical agent
  • Possible the system could identify liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE