Agilent Technologies, Inc. - Agilent 5975C Triple-Axis Detector GC/MSD System
Contact:

Agilent Technologies, Inc.

8825 Stanford Blvd. Suite 300

Columbia, MD 21045

POC: Beverly Lesko

beverly_lesko@agilent.com

443-285-7854

www.agilent.com/chem

System Cost: N/A
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
The Agilent 5975C TAD Series GC/MSD System uses Gas Chromatography and Mass Spectrometry to deliver high confidence results. The Triple-Axis HED EM Detector provides the flexibility, capabilities, and performance demanded by modern applications in all industries. The mass selective detector (MSD) is configured for electron ionization. The auto sampler systems can be selected to meet different requirements. Injection systems can range from an injector tower to a flexible CTC-PAL auto-sampling system. Other sampling devices are available from Agilent and third parties.
Technical Description
The Agilent 5975C TAD Series GC/MSD System uses Gas Chromatography and Mass Spectrometry to deliver high confidence results. The Triple-Axis HED EM Detector provides the flexibility, capabilities, and performance demanded by modern applications in all industries. The mass selective detector (MSD) is configured for electron ionization. The auto sampler systems can be selected to meet different requirements. Injection systems can range from an injector tower to a flexible CTC-PAL auto-sampling system. Other sampling devices are available from Agilent and third parties. Gold quartz quadrupole with proprietary design enhances both performance and reliability up to 1050 u, covering all applications from routine EI to 1050 u mass range extends system performance for all models, and delivers superior performance for even the most demanding high mass applications; industry’s lowest mass deviation ensures longer-lasting tuning and calibration demanding CI analyses. 350°C inert ion sources now programmable up to 350°C, delivers enhanced response for active compounds and late eluters. Trace Ion Detection technology Lowers detection limits in complex matrices; together with the high temperature inert ion source, this new technology gives your lab powerful new analytical capabilities. Synchronous SIM/Scan mode lets you selectively monitor for ions of interest at high sensitivity while simultaneously acquiring library-searchable scan data. All ionization modes in one automated sequence Electron impact (EI) ionization with standard Cl ion source; Auto CI feature makes CI as easy as EI. New hydrogen EI signal-to-noise specification permits faster analysis under safe conditions with no compromise on analytical quality.
Evaluation Criteria
THROUGHPUT:
  • Between 2 and 15 minutes for detection
  • Multiple samples, multiple tests/sample per run
  • 95-32 samples every 2 hours
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 10-20 minutes is required for setup
  • 1-2 steps are required for detection
LOGISTICS:
  • More than a day of training and significant technical skills are required
  • Approximately the size of a home dishwasher
  • More than 50 kg
  • Wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from 4°C to 41°C
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system could easily be adapted into a fully autonomous system
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • <1x10-6 mg/m3
  • < 1 ppb
  • System currently can identify aerosolized chemical agent
  • System currently can identify liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE