Meso Scale Diagnostics (MSD), LLC - Cartridge Reader
Contact:

Meso Scale Defense, a division of Meso Scale Diagnostics

(MSD®), LLC

POC: Charles Clinton

240-631-2522 x4617

cclinton@mesoscale.com

www.mesoscale.com

System Cost: N/A
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
The Cartridge Reader system uses MSD’s MULTI-ARRAY® electrochemiluminescence (ECL) technology to enable highly sensitive multiplexed immunoassay measurements in a compact, fully-automated format. The Cartridge Reader system consists of a compact reader instrument (12.5 lbs., 9” H x 8” W x 14” D) and single-use disposable cartridges that can conduct multiplexed measurements of up to 20 targets or controls per sample. The cartridges include integrated microfluidics to allow for fully automated sample processing and analysis without user intervention. Two cartridges types are available: one for analyzing liquid samples and the other for swab samples. To run an assay, the sample (liquid or swab) is inserted into the appropriate cartridge and the cartridge is then capped and loaded into the reader. All subsequent processing steps, including swab extraction (swab cartridge) and multiplexed ECL detection are fully automated. The system can detect and measure bacteria, viruses, and toxins with limits of detection many times lower than lateral flow immunoassays. The system is extremely simple to operate and provides a result in about 15 minutes. The Cartridge Reader system is still under development for laboratory and point-of-care clinical and environmental testing applications and is not yet commercially released. However, the instrument has been tested at DoD technology readiness evaluations (TREs) and has been through clinical evaluations in the U.S. and other locations worldwide for influenza diagnostics.
Technical Description
MSD’s PR2 and Cartridge Reader instruments employ MSD’s MULTI-ARRAY® technology that combines electrochemiluminescence (ECL) detection and array-based multiplexed measurements. ECL immunoassays enable highly sensitive measurement of samples for the presence of bacteria, viruses, and toxins. The measurements are performed on arrays printed on carbon ink electrodes that are incorporated into multi-well assay plates and cartridges. MULTI-ARRAY technology consistently has been demonstrated to provide high performance measurement capability in a wide range of matrices and in the presence of many interferents. While MULTI-ARRAY technology is primarily used for immunoassays, the technology can also be used for multiplexed nucleic acid measurements.
Evaluation Criteria
THROUGHPUT:
  • Between 15 and 30 minutes for detection
  • 1 sample, >10 tests/sample per run
  • Less than 32 samples every 2 hours
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 2 components
  • Less than 5 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a toaster
  • Between 5 and 25 kg
  • Wired connections are available
  • System or device has 110V electrical requirement
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from 4°C to 37°C
  • Components must be stored at 4°C
  • Performance is not influenced by relative humidity
  • Between 1 to 3 years shelf life
  • 5-10 years expected life
  • Results cannot be viewed in real-time
  • The system could be adapted to a fully autonomous system with some effort
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • Less than 250 µL
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • 1,000-10,000 CFU per mL
  • 10,000-100,000 PFU per mL
  • Less than 1 ng per mL
  • Spore lysis not necessary for detection by system
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE