CustomArray, Inc. - MX300
Contact:

CustomArray, Inc.

6500 Harbour Hts Pkway, Suite 202

Mukilteo, WA 98275

System Cost: $40,000
Analysis Cost: $170
Survey Source: Vendor Supplied Information
General Description
System for automating hybridization and reading of CustomArray DNA arrays, which can be used to detect organisms and genetic variants in laboratory settings. It is adaptable to any sample that has genetic material in it (either DNA or RNA).
Technical Description
Samples must be processed to extract nucleic acid material (using third-party kits), that material is then amplified (using a standard thermocycler), and the amplified material is put into the MX300 for hybridization to a DNA array and reading of results.
Evaluation Criteria
THROUGHPUT:
  • Between 60 minutes and 8 hours for detection
  • Between 60 minutes and 8 hours
  • Less than 32 samples every 2 hours
  • The system could be adapted to a fully automated system with some effort
  • Device or system is intended for multiple detection assays
  • 5 or more solutions, buffer, eluents, and/or reagents
  • Less than 5 minutes is required for set-up
  • Greater than 12 steps are required for detection
LOGISTICS:
  • More than a day of training and significant technical skills are required
  • Approximately the size of a home dishwasher
  • Between 25 and 50 kg
  • Satellite, wireless and wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from 4°C to 41°C
  • Components must be frozen (-20°C)
  • Performance is not influenced by relative humidity
  • Between 6 months and 1 year shelf life
  • 3-5 years expected life
  • Results cannot be viewed in real-time
  • The system could be adapted to a fully autonomous system with significant effort
  • The system software is open but modification requires licensing
  • The system hardware is open but modification requires licensing
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • Less than 10 µL
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • 1-100 CFU per mL
  • 1-100 PFU per mL
  • Less than 1 ng per mL
  • Manual kit not integrated with the system handles spore lysis
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE