FLIR Systems, Inc. - nanoRaider
Contact:

FLIR Systems, Inc.

2800 Crystal Drive, Suite 330

Arlington, VA 22202

410-540-8685

www.flir.com

System Cost: N/A
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
About the same size as a cellphone, the belt wearable nanoRaider provides continuous detection capability with visible, audible and tactile alerts. Once radiation has been detected, the fast identification capability of the instrument provides essential information to the user in the field, enabling them to make a next step determination. The One Touch ReachbackTM feature integrated into the nanoRaider allows the user to immediately send a notification to team members, superior officers, situation management personnel, and expert analysts – all with a single push of a button.
Technical Description
The nanoRaider uses uniquely constructed Cadmium Zinc Telluride (CZT) detectors that enable exceptional sensitivity and identification capabilities never before seen in a spectroscopic personal radiation detector (SPRD). The characteristic design of FLIR CZT detectors is more rugged than scintillation-based detectors and does not require temperature stabilization. The nanoRaider is also available with an optional neutron detector.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • Continuous operation with no defined runs
  • Greater than 750 samples every 2 hours
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • Less than 5 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a soda can
  • Between 5 and 25 kg
  • Wireless and wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from -21°C to 41°C
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system could easily be adapted into a fully autonomous system
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Less than 10 µL
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • Total dose, dose rate and count rate with operator selection to show the display, may differentiate between types of radiation
  • Down to background level radiation for dose rate
  • Down to background level radiation for count rate
  • System is used for surveying
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE