ANP Technologies, Inc. - NIDS-3000 BioThreat Detection Kit
Contact:

ANP Technologies, Inc.

824 Interchange Boulevard

Newark, DE 19711

POC: Yli Vallejo

System Cost: $4,500
Analysis Cost: $50
Survey Source: Vendor Supplied Information
General Description
The NIDS BioThreat Detection Kit uses next generation multiplexed lateral flow assays to analyze powders and waters for biothreats. Coupled with the handheld reader, results are as accurate as those in a laboratory setting. The assays have 5 targets per ticket, can be stored at room temperature for up to 3 years, and do not suffer from the Hook Effect, a false negative at high concentrations.
Technical Description
The next generation lateral flow assay uses our nano-manipulation technology that orients antibodies on the molecular level so that their biosensing region is always available for sensing, producing a highly sensitive assay that does not suffer from the Hook Effect as traditional lateral flow assays do.
Notes:
This system is the core technology in the DoD's Water Monitoring System.
Evaluation Criteria
THROUGHPUT:
  • Between 15 and 30 minutes for detection
  • Multiple samples, single tests/sample per run
  • 349-96 samples every 2 hours
  • The system could easily be adapted into a fully automated system
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 2 components
  • No set-up of the system is required
  • 1-2 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a soda can
  • Between 1 and 5 kg
  • Wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from 4°C to 37°C
  • Components must be stored at room temperature (27°C)
  • Performance is not influenced by relative humidity
  • Between 1 to 3 years shelf life
  • 5-10 years expected life
  • The system is not capable of autonomy
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • Less than 250 µL
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • 10,000-100,000 CFU per mL
  • Greater than 100,000 PFU per mL
  • 1-10 ng per mL
  • Spore lysis not necessary for detection by system
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE