GenPrime, Inc. - Prime Alert Biodetection System
Contact:

GenPrime, Inc.

157 S. Howard, Ste. 605

Spokane, WA 99201

POC: Buck Somes

Americas

System Cost: $10,500
Analysis Cost: $210
Survey Source: Vendor Supplied Information
General Description
The Prime Alert Biodetection/Threat Verification System is designed to allow First Responders to perform a rapid, on-site test to determine if a substance is a potential biohazard or merely a hoax. The simple and reliable technology alerts the responder to the presence of suspicious levels of any microbe in one five-minute test. A negative result is quickly followed by tests for ricin and botulinum toxins. In less than 15 minutes reliable information is obtained, allowing the First Response team to make an informed decision regarding incident closure. The Microbe Screen™ is performed using a proven fluorescent-based technology in a hand-held reader and the Toxin Screen™ is carried out using lateral flow antibody tests.
Technical Description
The Prime Alert is a broad spectrum point detection device designed for screening unknown substances for the presence of microbes. It employs a fluorescent nucleic acid stain with high affinity binding to DNA/RNA. The amount of fluorescence in a sample is correlative to the CFU’s, and is reported digitally on a handheld battery powered fluorometer. This value is used to make a qualitative assessment of the presence or absence of microbes in a sample.
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • 1 sample, <10 tests/sample per run
  • 95-32 samples every 2 hours
  • The system could be adapted to a semi-automated system with some effort
  • Device or system is intended for multiple detection assays
  • 3 solutions, buffer, eluents, and/or reagents
  • 3 components
  • Less than 5 minutes is required for set-up
  • 3-5 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Between 1 and 5 kg
  • Wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • Components must be stored at room temperature (27°C)
  • Performance is not influenced by relative humidity
  • Between 1 to 3 years shelf life
  • Results can be viewed in real-time
  • The system is not capable of autonomy
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • This system does not test liquids
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • Greater than 100,000 CFU per mL
  • Greater than 100,000 PFU per mL
  • 100-1,000 ng per mL
  • Spore lysis not necessary for detection by system
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE