General Description
The Agilent 700 Series ICP-OES Inductively Coupled Plasma Optical Emission Spectrometers are compact, bench mounted elemental analyzers for use in the laboratory. They are used for the simultaneous determination of trace to % levels of elements in a wide range of matrix types.
The Agilent 700 Series ICP-OES are the world’s most productive high-performance simultaneous ICP-OES. - Continuous wavelength coverage provides extended dynamic range and reduced interferences, giving you maximum confidence in your results
- Robust plasma ensures reliable and reproducible results — even with the most complex matrices
- One view, one step measurement of major, minor, and trace elements, plus the fastest warm-up, increases throughput and productivity
- Choice of optimized axial or radial configurations to suit your application needs
- Superior software features providing enhanced productivity and outstanding ease-of-use
Technical Description
A robust, argon based plasma is used to excite the elements of interest. The resultant emissions are directed through a thermostated, simultaneous echelle based optical system to a custom designed Peltier cooled CCD detector, allowing for fast simultaneous detection of elemental concentrations. Quantitative or semi-quantitative survey analysis modes are available. These instruments include a free-running, air-cooled 40 MHz RF generator with solid state HV power supply, purged echelle polychromator and full PC control of plasma viewing positioning and plasma gas flows. Fully web-integrated ICP Expert II software uses Agilent’s worksheet concept for ease of use, rapid operator training, and commonality with other Agilent spectroscopy products.
Evaluation Criteria
THROUGHPUT:
- Between 2 and 15 minutes for detection
- Multiple samples, multiple tests/sample per run
- 95-32 samples every 2 hours
- The system or device is currently fully automated
- Device or system is intended for multiple detection assays
- 2 solutions, buffer, eluents, and/or reagents
- 5 or more components
- 10-20 minutes is required for setup
- Almost instantaneous detection
LOGISTICS:
- More than a day of training and significant technical skills are required
- Larger than a home dishwasher
- More than 50 kg
- Wired connections are available
- System or device has 220V electrical requirement
OPERATIONS:
- Can be used from 25°C to 37°C
- Components must be stored at room temperature (27°C)
- Performance is not influenced by relative humidity
- Between 1 to 3 years shelf life
- Greater than 10 years expected life
- Results can be viewed in real-time
- The system could be adapted to a fully autonomous system with some effort
- The system software is closed and not available for modification
- The system hardware is closed and not available for modification
DETECTION:
- Possible the system could receive 510K clearance, no current efforts at this time
- Possible the system could receive FDA approval, no current efforts at this time
- Less than 250 µL
- Excellent specificity. System has occasional false alarms under certain conditions (<2%)