General Description
The radHUNTER is an extremely sensitive and accurate digital hand-held gamma radionuclide identification device (RID). It is the culmination of over eight years of development of micro-miniature, digital signal processing electronics; operating power conservation; and advancements in the scintillation detector, radionuclide template matching identification algorithm. The radHUNTER development was supported in part by the U.S. Government.
Technical Description
The radHUNTER is able to quickly detect, rapidly locate, accurately measure and precisely identify sources of contamination from their gamma radiation signature. The radHUNTER uses a 19 mm (0.7") thick by 102 mm (4.0") diameter NaI(Tl) detector or a 38 mm (1.5") thick by 38 mm (1.5") LaBr detector. This large cross section provides an excellent source to background ratio which rapidly locates gamma contamination. It comes with a GM tube for high gamma dose rate measurements and an optional sealed 3He detector with moderator for neutron detection.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • Continuous operation with no defined runs
  • Greater than 750 samples every 2 hours
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • Less than 5 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a toaster
  • Between 5 and 25 kg
  • Wireless and wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from -21°C to 41°C
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system could easily be adapted into a fully autonomous system
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • This system does not test liquids
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • Total dose, dose rate and count rate with operator selection to show the display, may differentiate between types of radiation
  • Down to background level radiation for dose rate
  • Down to background level radiation for count rate
  • System is used for personnel detection
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE