Detector Image Not Found
Average User Rating:

Technical Associates - Radiation Control Monitor
Contact:

Technical Associates

7051 Eton Ave.

Canoga Park, CA 91303

POC: Robert Goldstein, President

818-883-7043

System Cost: $9,500-$60,000
Analysis Cost: $0
Survey Source: Vendor and Internet Supplied Information
General Description
The Radiation Control Monitor can be tailored to at least 50 configurations meeting a variety of objectives in monitoring radioactivity including:
  • exit/doorway monitor
  • package/mail monitor
  • vehicle monitor
  • laundry monitor
To maintain control of radioactive materials it is absolutely essential to control and to know when and where radioactivity is entering or leaving the area where it is used. The Radiation Control Monitor consists of:
  • Multi-channel systems
  • Highly sensitive (50 detector models)
  • Alarms with detection of radiation
  • Relay control can lock doors and trigger a Siren or autodialer or e-mail
Two of the many radiation control monitor systems are high sensitivity monitors which are easily placed at entrance and exits and other strategic locations.
Technical Description
The Radiation Control Monitor includes:
  • Engineering Units: User can input correct conversion factor and change to any units.
  • Controls: Front Panel: On-Off, Alarm-mute, Rate, Integrate, Reset.
  • Recessed or Internal: Discriminator level, high voltage.
  • Detectors: Any GM or alpha, beta, gamma or neutron scintillator. Over 50 probes and sample detectors to choose from.
  • Input Sensitivity: Adjustable from less than 1 millivolt to 100 millivolt
  • Anti-saturation and Dead-time Corrections are available.
  • Power: 105-125 volts, 50-60 Hz (220 V optional)
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • 1 sample, <10 tests/sample per run
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 1 component
  • Less than 5 minutes is required for set-up
  • 1-2 steps are required for detection
LOGISTICS:
  • An afternoon of training and some technical skills required
  • Approximately the size of a carry-on luggage suitcase
  • Between 5 and 25 kg
  • Wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from 4°C to 41°C
  • Components must be stored at room temperature (27°C)
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • This system does not test liquids
  • System is used for area air sampling
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE