General Description
A handheld system for the military or first responder which allows the rapid detection, identification and geo-location of multiple radiation sources (Gamma). The system works with gamma radiation predominantly although a neutron module is available. The system uses an innovative processing system that allows the rapid discrimination, location and tracking of multiple sources simultaneously.
Technical Description
The system uses a multiple chipset of CZT crystals (exact configuration and numbers is proprietary) which have been bonded in such a way to allow cell discrimination - in a similar manner to the medical imaging industry. This is combined with highly advanced processing software used in advanced sonar systems for detecting and tracking multiple sources.
Evaluation Criteria
THROUGHPUT:
- 2 minutes or less for detection
- Continuous operation with no defined runs
- The system or device is currently fully automated
- Device or system is intended for multiple detection assays
- 0-1 solutions, buffer, eluents, and/or reagents
- Less than 5 minutes is required for set-up
- 1-2 steps are required for detection
LOGISTICS:
- Very brief (minutes-hours) training and minimal technical skills
- Approximately the size of a soda can
- Less than 1 kg
- Satellite, wireless and wired connections are available
- System or device uses batteries
- 2-4 hours battery life
OPERATIONS:
- Can be used from < -21°C to > 42°C (All temperatures)
- Performance is not influenced by relative humidity
- Greater than 3 years shelf life
- 5-10 years expected life
- Results can be viewed in real-time
- The system could easily be adapted into a fully autonomous system
- The system software is open and available for modification
- The system hardware is open and available for modification
DETECTION:
- This system does not test liquids
- System is used for surveying