Detector Image Not Found
Average User Rating:

ICx Biosystems - RapidPlex
Contact:

ICx Biosystems

505 Coast Boulevard South, Suite 309

La Jolla, CA 92037

POC: Michael Meyer

858-551-8827, x102

michael.meyer@icxt.com

System Cost: $45,000
Analysis Cost: <$70
Survey Source: Vendor and Internet Supplied Information
General Description
RapidPlex is a fully automated system for environmental monitoring of bacteria, viruses, and toxins. This advanced system has automated sample preparation, detects with high sensitivity, and identifies with high accuracy up to 20 different pathogens at once. Detected threats include toxins, DNA viruses, RNA viruses, bacteria, and bacterial spores. The RapidPlex identifier is capable of detecting at least 10-20 threat targets in a single test and utilizes multiple (2-3) independent biomarkers per threat target to ensure high levels of detection confidence and to minimize false positives, especially from non-pathogenic near-neighbors that are often present in the environment. The analyzer’s total analysis time is configurable dependent on sensitivity requirements, but in its most sensitive mode, provides sample-to-answer times of less than 30 minutes. RapidPlex was developed initially for unattended environmental monitoring, but is adaptable to other biodetection applications such as clinical diagnostics and food/water testing.
Technical Description
RapidPlex employs fast multiplex PCR to amplify DNA and RNA target sequences and a rapid multiplexed antibody sandwich assay for detection of toxins and surface proteins on viruses and bacteria. DNA amplicons and protein targets are detected by capturing them with specific capture probes on tens of thousands of microbeads. Each microbead is color coded to identify which threat hypothesis is being tested. This fluorescent imaging readout of thousands of assay microbeads enables coverage of a long threat list without the loss of sensitivity associated with sample splitting. The analyzer uses multiple molecular markers per threat to reduce false positives.
Evaluation Criteria
THROUGHPUT:
  • Between 15 and 30 minutes for detection
  • 1 sample, single test/sample per run
  • 349-96 samples every 2 hours
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 3 components
  • 5-10 minutes is required for set-up
  • 1-2 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a carry-on luggage suitcase
  • Between 25 and 50 kg
  • Wireless and wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from 25°C to 37°C
  • Components must be stored at room temperature (27°C)
  • Between 6 months and 1 year shelf life
  • Results cannot be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is open and available for modification
  • The system hardware is open and available for modification
DETECTION:
  • Less than 100 µL
  • 100-1,000 CFU per mL
  • 1,000-10,000 PFU per mL
  • 1-10 ng per mL
  • Fully automated spore lysis
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE