FLIR Systems, Inc. - STRIDE systems
Contact:

FLIR Systems, Inc.

2800 Crystal Drive, Suite 330

Arlington, VA 22202

410-540-8685

703-915-9014

www.flir.com

System Cost: N/A
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
STRIDE Detection Systems are available in a wide variety of sizes and features to detect and identify radioactive material. They can be openly or covertly installed in building entrances, at airports, bus or train stations, above or beside luggage or freight conveyer belts, by stadium entrances, ship ports and many more similar locations of potential risk.
Technical Description
A typical Detection Unit consists of a NaI scintillation detector for gamma radiation detection; DSP (Digital Signal Processing) based electronics with source or LED stabilization; a multichannel pulse height analyzer; a K40 source in the form of KCl for calibration verification and at times, stabilization; a usage appropriate enclosure; mains, battery or PoE (Power over Ethernet) power; and a data and control communication method.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • 5-10 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a carry-on luggage suitcase
  • Between 5 and 25 kg
  • Wireless and wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from -21°C to 41°C
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • This system does not test liquids
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • Total dose, dose rate and count rate with operator selection to show the display, may differentiate between types of radiation
  • Down to background level radiation for dose rate
  • Down to background level radiation for count rate
  • System is used for area air sampling
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE