RADeCO, Inc. - Tru-Dac
Contact:

RADeCO, Inc.

17 West PKWY

Plainfield, CT 06374

System Cost: $5,750
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
Tru-Dac is a personal Alarming Alph/Beta Monitor. Detects airborne radiation for inhalation dose in an ultra-portable package. The device can be used for either First Responders or Laboratory use. Utilizes a membrane filter. Collected airborne activity is analyzed by internal detector with Alpha spectroscopy and gross Beta counting.
Technical Description
Aerosol is collected at the surface of a filter. A semiconductor detector is used to Detect Alpha & Beta particles. Separation of long living Alpha Nuclides from Radon daughters by using alpha-spectroscopy. Beta gross counting and natural background subtraction is also included in the detection system.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently semi-automated
  • Device or system is intended for multiple detection assays
  • 1 component
  • Less than 5 minutes is required for set-up
  • 1-2 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a soda can
  • Less than 1 kg
  • Satellite, wireless and wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • Components must be stored at room temperature (27°C)
  • Performance is not influenced by relative humidity
  • 5-10 years expected life
  • Results can be viewed in real-time
  • The system could easily be adapted into a fully autonomous system
  • The system software is open but modification requires licensing
  • The system hardware is open but modification requires licensing
DETECTION:
  • This system does not test liquids
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • Only total dose and count rate
  • Down to background level radiation for dose rate
  • Down to background level radiation for count rate
  • System is used for personnel detection
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE