INFICON, Inc. - DataFID Flame Ionization Detector
Contact:

INFICON, Inc.

ChingYue Yeung, Product Manager

Two Technology Place

East Syracuse, NY 13057

www.inficon.com

System Cost: $11,495
Analysis Cost: <$1.00
Survey Source: Vendor Supplied Information
General Description
DataFID is a portable flame ionization detector (FID) that detects total volatile organic compounds (TVOCs) for leak detection and repair (US EPA Method 21) both in industrial settings and in the field.
Technical Description
DataFID uses flame ionization detection (FID) to measure total volatile organic compounds (TVOCs) in air at part per million (ppm) or part per billion (ppb) levels. When the DataFID hydrogen flame is ignited, the internal pump draws in air through the inlet, which provides the oxygen necessary for combustion. When the proper hydrogen-to-air ratio is present in the combustion chamber, a glow plug will automatically ignite the flame. TVOCs are ionized when the sample passes through the flame. These ionized molecules are subjected to a continuous electric field; the ions moving in this electric field generate a current that is proportional to the concentration of the ionized molecules in the combustion chamber. An electrometer circuit converts this current to a voltage which is sent to the microprocessor, and is displayed on the front panel as a concentration.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 3 components
  • Greater than 20 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical
  • skills
  • Approximately the size of a toaster
  • Between 5 and 25 kg
  • Wireless and wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from 4°C to 41°C
  • Components must be stored at room temperature (27°C)
  • Device or system has peak performance at normal relative
  • humidity conditions
  • 5-10 years expected life
  • Results can be viewed in real-time
  • The system is not capable of autonomy
  • The system software is closed and not available for
  • modification
  • The system hardware is closed and not available for
  • modification
DETECTION:
  • Not possible for the system to achieve 510K clearance
  • Not possible for the system to achieve FDA approval
  • This system does not test liquids
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE