Berkeley Nucleonics Corporation - Model 945 SAM III
Contact:

Berkeley Nucleonics Corporation

2955 Kerner Blvd.

San Rafael, CA 94901 U.S.A

System Cost: $13,500
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
The new, all-in-one, RIID from Berkeley Nucleonics offers customers a rugged alternative to detachable detectors with a full suite of new features leveraging modern cell phone technology. The renaissance in handheld electronics (Smartphone, PDA, etc.) has led to tremendous advancements in processing power and allows statistical calculations to be processed at a remarkable speed. In parallel, the processors managing the spectral collection and isotope identification can easily handle a myriad of exciting additional user requirements. The long list of much-awaited features ensure new users and experienced health physicists alike will enjoy an unmatched user experience when performing mission critical tasks. PeakAbout, a free app that manages the data and reporting of the SAM 945, boasts a comprehensive library of 115 isotopes with expansion possibility to 393 isotopes.
Technical Description
The spectroscopy is a breakthrough in ANSI isotope identification accuracy and speed. Our faster wavelet transform enables instantaneous results with confidence factors that grow exponentially each second. This new algorithm coupled with real-time background correction provides higher sensitivity, rejection of false positives due to changes in background and a linear energy axis. The library is customizable and color coded, with ANSI being the users default.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • Multiple samples, multiple tests/sample per run
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently semi-automated
  • Device or system is intended for multiple detection assays
  • Less than 5 minutes is required for set-up
  • 3-5 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a toaster
  • Between 1 and 5 kg
  • Satellite, wireless and wired connections are available
  • There is no electrical requirement
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • This system does not require consumable components
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system is not capable of autonomy
  • The system software is open but modification requires licensing
  • The system hardware is open but modification requires licensing
DETECTION:
  • Not possible for the system to achieve FDA approval
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • Total dose, dose rate and count rate with simultaneous display readout and automatic differentiation between types of radiation detected
  • Down to background level radiation for dose rate
  • Down to background level radiation for count rate
  • System is used for surveying
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE