Chemring Detection Systems - PGR-1064™
Contact:

Chemring Detection Systems

Boyd Despard

4205 Westinghouse Commons Drive

Charlotte, NC 28273

System Cost: $32,500
Analysis Cost: $0
Survey Source: Vendor Supplied Information
General Description
PGR-1064™ provides actionable data through handheld narcotic, explosive and chemical identification device that utilizes Raman spectroscopy. Solids and liquids are identified without sample preparation. The Raman 1064 nm wave source is not susceptible to water interference. A key differentiator of the PGR-1064™ from other products is that it can prevent substance contamination and provide safety benefits because samples can be analyzed through clear and colored plastic and glass containers. Additionally, 1064 nm allows the detection of chemicals such as Semtex, degraded TNT and potassium permanganate that would otherwise be blind to fluorescence with the 785 nm wave source technology. PGR-1064™ can typically capture, analyze and identify a substance in less than 10 seconds. PGR-1064™ Benefits Include:
  • Lighted Screen
  • Handheld Pistol Grip
  • Immediate Start-up
  • Straightforward Menu of Options
PGR-1064™ Technology Features:
  • Identifies chemicals that are susceptible to fluorescence at 785nm
  • Able to identify >5000 chemicals
  • Expandable, customizable and qualified (by category) library
  • Recordable spectra for further analysis and evidence retrieval
  • Maximum potential discriminating power - Category A (DoJ Scientific Working Group)
  • Quantifiable Results
  • Mixture Analysis
  • Ruggedized (Meets MIL-STD 810G, IP67 Compliant)
  • Training in Under 1 hour
  • Lightweight < 1.0kg
  • Battery Life of up to 12 Hours
Technical Description
PGR-1064™ Pistol Grip Raman's spectrometer identifies solid and liquid chemical samples with a typical analysis time of less than 10 seconds. From a composite database of over 5000 elements, PGR-1064™ identifies explosives, TICs, CWAs, and narcotics in fielded environments. The 1064 nm Raman laser mitigates both sample and background fluorescence, allowing PGR-1064 to reliably identify more substances in more situations.PGR-1064™ utilizes Raman Spectroscopy and an on board processor that compares the sample to the Raman signature compound library. Raman Spectroscopy is a precise and selective optical technique and is accepted by the Scientific Working Group for the Analysis of Seized Drugs (SWGDRUG) as a Category A analytical technique. A correlation algorithm identifies the best match and notifies the operator of the result. PGR-1064™ screens through most common clear or translucent containers without opening the container or compromising the integrity of the sample.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • 1 sample, single test/sample per run
  • 349-96 samples every 2 hours
  • The system or device is currently semi-automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • No set-up of the system is required
  • 1-2 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a soda can
  • Less than 1 kg
  • Wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • This system does not require consumable components
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system could easily be adapted into a fully autonomous system
  • The system software is open and available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Not possible for the system to achieve 510K clearance
  • Not possible for the system to achieve FDA approval
  • Less than 250 μl
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • > 1 ppt
  • Not possible for the system to identify aerosolized chemical agent
  • System currently can identify liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE