Research International, Inc. - RSN 5100
Contact:

Research International, Inc.

17161 Beaton Road SE

Monroe, WA 98272

POC: Jonathon Tobelmann

703-625-8381

www.resrchintl.com

System Cost: $25,000-60,000
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
The Remote Sensor Node 5100 (RSN 5100) is a field-portable instrument system that uses multiple technologies to monitor for the presence of chemical, biological, radiological and nuclear threats. It is the only product of its kind currently available in the world, integrating detection technologies from the world's leading suppliers into a complete, networked CBRN monitoring solution. It has been developed for use in military, homeland security, public safety and public health applications. The RSN 5100 is modular in design and can be configured with all or just some of the sensor subsystems depending on customer requirements.

Available sensors include:

  • State-of-the-art chemical detectors
  • An ultraviolet fluorescence-based biological particle detector for suspicious changes in bioaerosol concentrations.
  • A sensitive gamma ray detector that detects suspicious changes in background radiation.
If alarm levels are exceeded, a secondary air sampling circuit is automatically activated to collect a permanent aerosol particle sample onto a special high efficiency filter element. Any particulates collected can then be analyzed with a portable or laboratory-based biological, chemical or radiological system.
Technical Description
The RSN 5100 normally operates in a background monitoring mode. In this condition it samples air at 2 liters/minute. The air stream is analyzed with anion mobility spectrometer to detect and identify chemical warfare agents. It is further analyzed with an array of 6 electrochemical gas detectors for common toxic industrial chemicals. A gamma ray monitor is used to detect radiation in the air sample. Finally, this air sample is tested for suspicious increases in bioaerosol concentration with the TacBio bioaerosol monitoring instrument. This device passes the air stream through an optical chamber where particulates are irradiated with 365 nm light. Both fluorescence signals and photon scattering events are collected and analyzed to look for an increase in biological particle concentration. If an instrument alarms (or under remote control), an embedded air sampler, based on the SASS 3100, is turned on which collects particulates at 300 liters/minute onto a proprietary electret filter for later analysis of captured biological or other particulates.
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • Continuous operation with no defined runs
  • 349-96 samples every 2 hours
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • Greater than 20 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a carry-on luggage suitcase
  • Between 5 and 25 kg
  • Wireless and wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • This system does not require consumable components
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is open but modification requires< licensing
  • The system hardware is closed and not available for modification
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • This system does not test liquids
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • > 1x10-3 mg/m3
  • 1 ppm-100 ppm
  • System currently can identify aerosolized chemical agent
  • System currently can identify liquid chemical agent
  • Only dose rate
  • Down to background level radiation for dose rate
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical