Luxfer Magtech - M18A3 Chemical Agent Detector Kits
Contact:

Luxfer Magtech

2940 Highland Avenue, Unit 210

Cincinnati, OH 45212

Tel: 800-503-4483

System Cost: Single Kit: $1,288Case, 24 Kits: $17,760
Analysis Cost: N/A
Survey Source: Vendor Supplied Information
General Description
The M18A3 Chemical Agent Detector Kit is designed primarily for detecting dangerous concentrations of vapors, aerosols, and liquid droplets of the chemical agents listed below. This kit will be used primarily by chemical specialty personnel assigned at the organizational level. This kit's capability provides for the sampling of unknown NBC agents. If a chemical agent is suspected but cannot be detected with the kit, vapor samples can be collected in sampling tubes for forwarding to a laboratory for identification. The principle uses of the kit are:
  • For reconnaissance in areas suspected of chemical agent contamination.
  • For finding the boundaries of contaminated areas.
  • For determining the absence of a chemical agent so that following a chemical attack, unmasking can occur.
  • For testing for the presence of a chemical agent after decontamination.
  • For collecting samples of suspected but unidentified chemical agents.
Technical Description
Agents listed below are detected by the M18A3 Chemical Agent Detector Kit:
  • Cyanogen Chloride (CK)
  • Mustards [(H), (HD), (HN), and (HT)]
  • Phosgene Oxime (CX)
  • Hydrocyanic Acid (AC)
  • Phosgene (CG)
  • Lewisite (L)
  • Ethyl Dichloroarsine (ED)
  • Methyl Dichloroarsine (MD)
  • Nerve Agents (V- and G-agents)
Evaluation Criteria
THROUGHPUT:
  • Between 2 and 15 minutes for detection
  • 1 sample, single test/ sample per run
  • The system or device is currently semi-automated
  • Device or system is designed for a single use
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • No set-up of the system is required
LOGISTICS:
  • An afternoon of training and some technical skills required
  • Approximately the size of a toaster
  • Less than 1 kg
  • This system is not capable of transmitting data
  • There is no electrical requirement
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • The system is not capable of autonomy
  • The system does not employ any software
  • The system is single use or this question does not apply to this device
DETECTION:
  • Not possible for the system to achieve clearance
  • Not possible for the system to achieve approval
  • This system does not test liquids and this question does not apply
  • > 1x10-3 mg/m3
  • Does not detect liquid samples
  • System can identify aerosolized chemical agent
  • System can identify liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE