Detector Image Not Found
Average User Rating:

Tradeways - M9 Paper
Contact:

Tradeways

www.GasMasks.com

System Cost: $1
Analysis Cost: $1
Survey Source: Vendor Supplied Information
General Description
M9 chemical detection papers were originally developed for the military to detect liquid nerve and blister agents. M9 Chemical Detection is used by ground forces and is placed on personnel and equipment to identify the presence of liquid chemical agent aerosols. It contains a suspension of an agent sensitive red indicator dye in a paper matrix. It will detect and turn pink, red, reddish brown or redpurple when exposed to liquid nerve agents and blister agents, but it does not identify the specific agent, nor does it detect any biological agents, such as anthrax.
Technical Description
M9 Paper is actually a coated tape with a mylar-adhesive backing so it can be affixed to objects. It's packaged in a dispenser with a serrated edge to easily tear off sections for use. M9 contains a suspension of an agent-sensitive red indicator dye on the paper. The dye will turn pink, red, reddish-brown, or red-purple when exposed to a liquid agent. Agents do not react directly with the dyes in M8 paper, but rather, dyes react to the unique acidity of each of the agents to produce the color change in a manner similar to litmus paper. M9 Paper can detect agents, but not identify which agents are present. The tape that makes up M9 is 9.1 meters long and 5.1 centimeters wide. The selfadhesive paper attaches to most surfaces, and a moisture proof resealable bag is provided to store the dispenser after removal from its original packaging.
Evaluation Criteria
THROUGHPUT:
  • Detection is instantaneous
  • 1 sample, single test/ sample per run
  • Less than 32 samples every 2 hour
  • The system or approach is not amenable to full or semiautomation
  • Device or system is designed for a single use.
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • No set-up of the system is required
  • No steps for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a soda can
  • Less than 1 kg
  • This system is not capable of transmitting data
  • There is no electrical requirement
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • This system does not require consumable components
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • This system or device is single use and does not have an expected life
  • Results can be viewed in real-time
  • The system is not capable of autonomy
  • The system does not employ any software
  • The system is single use or this question does not apply to this device
DETECTION:
  • Not possible for the system to achieve clearance
  • Not possible for the system to achieve approval
  • Not possible for the system to achieve approval
  • Poor specificity. System has a consistently high level of false alarms (>10%)
  • 1 ppm - 100 ppm
  • Not possible to identify aerosolized chemical agent
  • System can detect liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE