General Description
Apollo is a high-efficiency radioisotope identification device (RIID) with better than 1% FWHM energy resolution and gamma-ray imaging.
  • Comparable resolution to HPGe, but go from storage to measurement in 90 s
  • Detection times equivalent to 2" NaI(Tl) [M. Streicher et al., 2014 IEEE NSS/MIC, Seattle, WA, p.1-3.]
  • Full imaging of each isotope's distribution over all directions
  • Automated isotope-specific localization; pinpoint the location of each isotope
  • Automated identification, and library selectable from full 3573-isotope ENDF library
  • IP52 ingress protection for field use
  • Wireless connectivity to optional base station with full oversight capability
  • Data playback and post-processing tool included
  • Works in high dose (500 mrem/hr) environments
  • Full warranty and updates for 2 years
Technical Description
The imaging gamma spectrometer is based on pixelated CdZnTe (CZT) detector technology. The ability to record the position and energy of the detected gamma ray allows for the simultaneous identification and location of a source.
Evaluation Criteria
THROUGHPUT:
  • Between 2 and 15 minutes for detection
  • Continuous operation with no defined runs
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently semi-automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 0 components
  • Less than 5 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • An afternoon of training and some technical skills required
  • Approximately the size of a toaster
  • Between 1 and 5 kg
  • System or device uses batteries
  • 4-8 Hours battery life
OPERATIONS:
  • Can be used from 4°C to 41°C
  • This system does not require consumable components
  • Performance is not influenced by relative humidity
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system could easily be adapted into a fully autonomous system
DETECTION:
  • This system does not test liquids and this question does not apply
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • Total dose, dose rate and count rate with operator selection to show the display, may differentiate between types of radiation
  • Down to background level radiation (i.e., gamma 1 µR/hr)
  • Down to background level radiation, expressed in cpm or similar units
  • System is used for surveying
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE