Detector Image Not Found
Average User Rating:

Building Protection Systems, Inc. (BPSI) - ALPHA SENTRY ONE
Contact:

Building Protection Systems, Inc. (BPSI)

150 Post Street, Suite 750

San Francisco, CA 94108

POC: Greg Eiler President

925-933-8600

geiler@bpsiglobal.com

www.bpsiglobal.com

System Cost: N/A
Analysis Cost: $0
Survey Source: Vendor Supplied Information
General Description
The Alpha Sentry One (ASO) is a U.S. Department of Homeland Security SAFETY Act Designated technology installed to monitor terrorist concerns of smaller venues such as a Commercial Office Building lobbies, perimeter protection and schools. Using the same sensory technology as the larger Building Sentry One, the ASO is limited to (2) or (4) sensors. If a toxin is detected, the ASO enacts a sequence of predetermined alerts and mechanical protocols to isolate toxins thus preventing continued distribution to prevent loss of life, preserve assets, and to provide an early warning system for first responders in the event of a targeted terrorist attack using chemical or radiological materials or an accidental release. The ASO is installed as an all-in-one full backbone system and can integrate directly into an existing Building Management System (BMS) or security command center. The ASO detects a defined spectrum of chemical contaminants and a wide library of radiological isotopes with sensitivity levels customized for each specific toxin. The ASO has been designed in modular fashion for a quick deployment with easy installation. No known similar systems exist. The Alpha Sentry One is a fully functioning “Next Generation” detection system that can integrate sensory technology into just about any market ready project. With embedded controls, logic, software, mechanical protocols and remote monitoring coupled with multiple security means, this system is designed to operate 24/7/365 in the absence of false positive readings.
Technical Description
BPSI’s Alpha Sentry One (ASO) is a COTS based system that detects a defined spectrum of toxic compounds and a 120+ library of radiological isotopes for smaller applications such as: perimeter protection, schools or building lobbies on a continuous 24/7/365 basis with virtually zero false positive alarms. Through the integration of programmable logic controllers and sensor arrays, linked to a PC infrastructure with multi-layer communications protocols, the Alpha Sentry One solution offers a dynamic set of customized security measures. The ASO’s architecture mesh simply and easily with existing systems, in a seamless process that gives the end user superior detection protection.
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • Multiple samples, multiple tests/sample per run
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 1 component
  • No set-up of the system is required
  • 1-2 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a toaster
  • Between 1 and 5 kg
  • Wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from 4°C to 41°C
  • This system does not require consumable components
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is open and available for modification
  • The system hardware is open and available for modification
DETECTION:
  • Not possible for the system to achieve 510K clearance
  • Not possible for the system to achieve FDA approval
  • This system does not test liquids
  • Superior specificity. System has a false alarm rate
  • approaching zero (~0%)
  • Add on capability that is full or semi-automated for spore lysis
  • 1x10-6 - 3x10-5 mg/m3
  • System currently can identify aerosolized chemical agent
  • Not possible to identify liquid chemical agent
  • Total dose, dose rate and count rate
  • Down to background level radiation for dose rate
  • Down to background level radiation for count rate
  • Area air sampling
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE