Applied Biosystems - ViiA 7 Real-Time PCR System
Contact:

Applied Biosystems

850 Lincoln Centre Drive

Foster City, CA 94404

650-638-5800

www.appliedbiosystems.com

System Cost: $71,000
Analysis Cost: $1-2
Survey Source: Vendor Supplied Information
General Description
ViiA 7 Real-Time PCR System can serve various purpose from testing environmental samples, verifying and quantifying bacterial or viral existence, and validating DNA/RNA sequence existence.
Technical Description
Instrument that employs real-time TaqMan® polymerase chain reaction amplification of genes on a peltier-based thermocycling apparatus. The ViiA 7 Real-Time PCR System is available in 384-well, 96-well, Fast 96-well or proprietary TaqMan Array 384-well low volume format.
Evaluation Criteria
THROUGHPUT:
  • Between 60 minutes and 8 hours for detection
  • Multiple samples, multiple tests/sample per run
  • Greater than 750 samples every 2 hours
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 5 or more solutions, buffer, eluents, and/or reagents
  • 2 components
  • Less than 5 minutes is required for set-up
  • 1-2 steps are required for detection
LOGISTICS:
  • An afternoon of training and some technical skills required
  • Approximately the size of a home dishwasher
  • More than 50 kg
  • Wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from 4°C to 37°C
  • Components must be stored at 4°C
  • Performance is not influenced by relative humidity
  • Between 6 months and 1 year shelf life
  • 5-10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is open but modification requires licensing
  • The system hardware is open but modification requires licensing
DETECTION:
  • Efforts are underway to achieve 510K clearance
  • Efforts are underway to achieve FDA approval
  • This system does not test liquids
  • Superior specificity. System has a false alarm rate approaching zero (~0%)
  • Spore lysis not necessary for detection by system
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE