RAE Systems, Inc. - AreaRAE GAMMA Steel
Contact:

RAE Systems, Inc.

3775 N. First Street

San Jose, CA 95134

POC: Jim Kane 757-746-5554

jkane@raesystems.com

System Cost: $9,594
Analysis Cost: N/A
Survey Source: Vendor and Internet Supplied Information
General Description
The AreaRAE Gamma is a combination multi-gas and radiation detector equipped with a wireless, RF (radio-frequency) modem that allows the unit to communicate and transmit sensor and other information on a real-time basis with a remotely located base controller. In the stand alone operation, the AreaRAE Gamma is a rugged, weather-resistant, one-to-five sensor portable monitor that can run up to 18 hours on either rechargeable Lithium-ion or optional alkaline batteries. It is also the first “lunchbox”- type multi-sensor instrument able to include a gamma sensor for measurement of gamma radiation, a photoionization detector (PID) for parts per-million measurement of volatile organic compounds (VOCs), as well as an LEL combustible gas sensor, oxygen sensor, and a selectable electrochemical toxic sensor. Key Features: Up to four gas sensors (PID, LEL, O2 and selectable toxic gas) One radiation sensor (Gamma) Loud buzzer and large, extra-bright warning light Large LCD display and keypad Rugged, weather-resistant housing Built-in sampling pump Interchangeable Lithium-ion or alkaline battery pack Continuous operation via AC source Additional Advantages Real-time wireless data transmission with built-in RF modem View real-time sensor data and alarm status at headquarters or command center Optional GPS provides ability to track and display readings from remote detectors License-free, ISM-band RF transmission with communication range up to 2 miles.
Technical Description
In addition to the Scintillation Crystal Detector, the AreaRAE GAMMA has a photoionization detector (PID) which uses an ultraviolet lamp and sensor to detect volatile organic compounds (VOCs) and halocarbons.
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • Multiple samples, single tests/sample per run
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 5 or more components
  • 5-10 minutes is required for set-up
  • 1-2 steps are required for detection
LOGISTICS:
  • An afternoon of training and some technical skills required
  • Approximately the size of a toaster
  • Between 1 and 5 kg
  • Satellite, wireless and wired connections are available
  • System or device uses batteries
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from -21°C to 41°C
  • This system does not require consumable components
  • Device or system has peak performance at normal relative humidity conditions
  • Between 6 months and 1 year shelf life
  • 5-10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is open but modification requires licensing
  • The system hardware is open but modification requires licensing
DETECTION:
  • Not possible for the system to achieve 510K clearance
  • Not possible for the system to achieve FDA approval
  • This system does not test liquids
  • 1 ppm-100 ppm
  • Possible the system could be adapted to identify liquid chemical agent
  • Only count rate
  • Down to background level radiation for count rate
  • System is used for surveying
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier