Battelle - Pacific Northwest National Laboratory Biodetection Enabling Analyte Delivery System (BEADS)
Contact:

Battelle - Pacific Northwest National Laboratory

P.O. Box 999, Battelle Blvd.

Mail Stop P7-50

Richland, WA 99352

Attn: Dr. Richard M. Ozanich

richard.ozanich@pnl.gov

www.pnl.gov

System Cost: $1,000-$4,000
Analysis Cost: $10-$20
Survey Source: Vendor Supplied Information
General Description
BEADS is a universal fluidics platform that enables automated processing of surface functionalized magnetic and non-magnetic beads. BEADS enables faster more sensitive assays for a wide range of biothreat targets including DNA/RNA, bacteria, viruses, spores, oocytes, proteins, etc. BEADS enables a high degree of sample purification and concentration and is applicable for a broad range of matrices. BEADS serves as a front-end to a variety of detectors (e.g., PCR, Flow Cytometry, Electrochemical detectors, Fluorescence or Absorbance Detectors, etc.) or can be integrated with robotic systems . BEADS can serve as a sample purification and concentration front-end, or detectors can be integrated within BEADS.
Technical Description
The key enabling technology is a bead trap/flow-cell. The flow cell isolates surface functionalized magnetic or non-magnetic beads in a mini-column, which allows sample, reagents, and wash solutions to be passed over the bead column, resulting in significantly improved mass transport and faster, more sensitive assays. The microbeads can be functionalized with a wide range of target analyte capture ligands including oligonucleotides, antibodies and lectins. Semi-selective beads (e.g., silica, hydroxyapatite) can also be used to capture a wide range of pathogens or nucleic acids utilizing electrostatic capture.
Evaluation Criteria
THROUGHPUT:
  • Between 2 and 15 minutes for detection
  • 1 sample, <10 tests/sample per run
  • Less than 32 samples every 2 hours
  • The system could be adapted to a fully automated system with some effort
  • Device or system is intended for multiple detection assays
  • 3 solutions, buffer, eluents, and/or reagents
  • 1 component
  • Less than 5 minutes is required for set-up
  • 1-2 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a carry-on luggage suitcase
  • Between 5 and 25 kg
  • Satellite, wireless and wired connections are available
  • System or device has 110V electrical requirement
  • 4-8 hours battery life
OPERATIONS:
  • Can be used from 4°C to 41°C
  • Components must be stored at 4°C
  • Performance is not influenced by relative humidity
  • Between 6 months and 1 year shelf life
  • 3-5 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is open and available for modification
  • The system hardware is open and available for modification
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • Less than 10 µL
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • 1-100 colony forming units (CFU) per mL
  • 1-100 plaque forming units (PFU) per mL
  • Add on capability that is full or semi-automated for spore lysis
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE