Detector Image Not Found
Average User Rating:

THALES Defense&Security - BIOWARD
Contact:

THALES Defense&Security

C4I Systems Division

20-22 rue Grange Dame Rose CS

90519 78141 Velizy Cedex

POC: Jerome Louat

jerome.louat@Thalesgroup.com

www.thalesgroup.com/uk

System Cost: N/A
Analysis Cost: N/A
Survey Source: Vendor and Internet Supplied Information
General Description
The BIOWARD is a portable aerosol dosimeter. It is designed to be carried by a non-specialist soldier or a first responder all along his mission, even several days, to record a sample of the aerosols he is breathing. The device can be used for any kind a threat, be it biological, chemical or radiological, as long as it is present as aerosol.
Technical Description
The BIOWARD use a filter sampling principal, with a flow rate mirroring human breath. It can achieve a operational autonomy of several days. The filter itself can be adapted to the threat.
Evaluation Criteria
THROUGHPUT:
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 1 component
  • No set-up of the system is required
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a soda can
  • Less than 1 kg
  • This system is not capable of transmitting data
  • System or device uses batteries
OPERATIONS:
  • Can be used from 25°C to 37°C
  • Can be used from < -21°C to > 42°C (All temperatures)
  • Components must be stored at room temperature (27°C)
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • 3-5 years expected life
  • Results cannot be viewed in real-time
  • The system or device is currently fully autonomous
  • The system hardware is closed and not available for modification
DETECTION:
  • Not possible for the system to achieve 510K clearance
  • Not possible for the system to achieve FDA approval
  • This system does not test liquids
  • Not possible for the system to identify aerosolized chemical agent
  • Not possible for the system to identify liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE