MIT Lincoln Laboratories - CALS (Chemical Agent Line Sensor)
Contact:

MIT Lincoln Laboratories

244 Wood Street

Lexington, MA 02420

POC: Benjamin L. Ervin, Ph.D.

339-223-5332 or 781-981-5124

ben.ervin@LL.mit.edu

System Cost: $70,000
Analysis Cost: N/A
Survey Source: Vendor and Internet Supplied Information
General Description
The Chemical Agent Line Sensor (CALS) detects and identifies releases of chemical warfare agents (CWAs) and toxic industrial agents (TICs) over a line path. The system can be used by several types of large open-volume facilities to determine whether a covert chemical release is occurring. It was specifically designed for low maintenance, no consumables, low cost, rapid deployment, and high detection performance to fit a wide array of facility constraints.
Technical Description
The CALS system is an open path Fourier Transform Infrared (FTIR) chemical sensor. The system transmits Long Wave Infrared (LWIR) energy from a filament to a spectrometer spatially partitioned from the transmitter. The amount of absorbance at each wavelength is measured and used to identify the amount and type of agent present between the transmitter and receiver.
Notes:
Not to be confused with the DoD's Common Analytical Laboratory System (CALS) which shares the same acronym.
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • Multiple samples, single tests/sample per run
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 10-20 minutes is required for set-up
  • 1-2 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a carry-on luggage suitcase
  • More than 50 kg
  • Satellite, wireless and wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from < -21°C to > 42°C (All temperatures)
  • This system does not require consumable components
  • Greater than 3 years shelf life
  • Greater than 10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is open and available for modification
  • The system hardware is open and available for modification
DETECTION:
  • Not possible for the system to achieve 510K clearance
  • Not possible for the system to achieve FDA approval
  • This system does not test liquids
  • System can currently identify aerosolized chemical agent
  • Not possible for system to identify liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical