Detector Image Not Found
Average User Rating:

Ciencia, Inc. - FluorSPR
Contact:

Ciencia, Inc.

111 Roberts Street, Suite K

East Hartford, CT 06108

POC: Arturo O. Pilar, President

860-528-9737

apilar@ciencia.com

System Cost: $80,000
Analysis Cost: $150
Survey Source: Vendor Supplied Information
General Description
Ciencia's FluorSPR is a dual-mode microarray instrument platform combining a surface plasmon resonance (SPR) analyzer with a surface plasmon coupled emission (SPCE) mode. In its SPR mode it provides capabilities equal to or superior to competing SPR instruments, offering highly multiplexed measurements of high molecular weight analytes in real time. The SPCE mode produces highly directional fluorescence enabling detection in the femptomolar range. The dual-mode instrument is specifically designed to chemically capture (using antibodies, aptamers) and quantify the pattern of cytokines secreted.
Technical Description
The instrument combines Grating-coupled Surface Plasmon Resonance and Surface Plasmon Coupled Emission functionality into one instrument. Detection of all analytes present in a single sample occurs simultaneously. The specificity depends on antibody or aptamer selection and binding. Detection depends on the mass of analyte captured or an enhanced fluorescence signal.
Evaluation Criteria
THROUGHPUT:
  • Between 30 and 60 minutes for detection
  • 1 sample, >10 tests/sample per run
  • Less than 32 samples every 2 hours
  • The system or device is currently semi-automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • 1 component
  • Less than 5 minutes is required for set-up
  • Automatic detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Approximately the size of a carry-on luggage suitcase
  • Between 5 and 25 kg
  • Wired connections are available
  • System or device has 110V electrical requirement
OPERATIONS:
  • Can be used from 4°C to 41°C
  • Components must be stored at 4°C
  • Between 6 months and 1 year shelf life
  • 5-10 years expected life
  • Results can be viewed in real-time
  • The system is not capable of autonomy
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Possible the system could receive 510K clearance, no current efforts at this time
  • Possible the system could receive FDA approval, no current efforts at this time
  • Less than 100 µL
  • Excellent specificity. System has occasional false alarms under certain conditions (<2%)
  • 10,000-100,000 CFU per mL
  • 10,000-100,000 PFU per mL
  • 10-100 ng per mL
  • Spore lysis not necessary for detection by system
  • Possible system could be adapted to identify aerosolized chemical agent
  • System current can identify liquid chemical agent
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE