Detector Image Not Found
Average User Rating:

Polimaster, Inc. - Combined Gamma Dosimeter and Chemical Agent Detector PM2012M
Contact:

Polimaster, Inc.

112, Bogdanovich str.

Minsk 220040, Republic of Belarus

POC: Mr.Yury Kurlovich, Managing Director

+375 17 2177083

polimaster@polimaster.com

www.polimaster.us

System Cost: $7,282
Analysis Cost: $500
Survey Source: Vendor and Internet Supplied Information
General Description
Combined Gamma Dosimeter and Chemical Agent Detector PM2012M is a two-in-one instrument featuring chemical detector and gamma radiation detector in one unit. The device is designed to detect chemical warfare agents and toxic compounds and differentiate between organophosphorus and arsenic-containing compounds, as well as continuously monitor radiation background, measure gamma dose and dose rate and provide audible, visual alarms when preset thresholds are exceeded is invaluable for first responders, police officers, military, and customs and border patrol services in the day-to-day monitoring of public safety as well as in special HazMat operations. It can be used as a personal detector, a monitor for surveying contaminated areas, or as a fixed-installed detector
Technical Description
For Combined Gamma Dosimeter and Chemical Agent Detector PM2012M: Instrument’s operation principle in the TCV air presence detection mode is based on toxic chemical vapors detection module. Instrument measures current strength of the ionization chamber with beta-source 63Ni. Analyzed air at that is forcedly pumped through the chamber by micro purge pump. Microprocessor-based controller with internal analog-digital converter controls GEDM and TCVDM modules. Instrument operation algorithm enables continuous measurement of ambient dose equivalent of gamma- and roentgen radiation Н*(10) , measurement of photon emission ambient dose equivalent Н*(10) and detection of toxic vapors air presence, statistical analysis of measurement data, and quick adaptation to variations of radiation strength (setting of measurement time periods irreversibly to radiation strength). Internal non-volatile instrument’s memory accumulates and stores information. IR-link is used for MPC-PC information communication.
Evaluation Criteria
THROUGHPUT:
  • 2 minutes or less for detection
  • Multiple samples, multiple tests/sample per run
  • System is continuous and provides real time analysis with no defined tests/samples
  • The system or device is currently fully automated
  • Device or system is intended for multiple detection assays
  • 0-1 solutions, buffer, eluents, and/or reagents
  • Less than 5 minutes is required for set-up
  • 1-2 steps are required for detection
LOGISTICS:
  • Very brief (minutes-hours) training and minimal technical skills
  • Less than 1 kg
  • Wireless and wired connections are available
OPERATIONS:
  • Performance is not influenced by relative humidity
  • Greater than 3 years shelf life
  • 5-10 years expected life
  • Results can be viewed in real-time
  • The system or device is currently fully autonomous
  • The system software is closed and not available for modification
  • The system hardware is closed and not available for modification
DETECTION:
  • Not possible for the system to achieve 510K clearance
  • Not possible for the system to achieve FDA approval
  • This system does not test liquids
  • Total dose and dose rate
  • System is used for surveying
Tier Selection
BioImageChemImageRadImage
Field Use
Mobile
Diagnostic
Analytical
Tier Key:
Tier 1 Top Tier
Tier 2 Second Tier
Tier 3 Third Tier
Tier 4 Fourth Tier
Tier 5 Bottom Tier
Scoring Analysis
Bar Chart Image Not Found
Impact Chart
Impact Chart Image Not Found
FIELD USE
MOBILE USE
DIAGNOSTIC USE
ANALYTIC USE